Technopol SA · Engineering calculator

LiteCel CD Board & Tie Calculator

Wall in, boards and ties out. SANS 10164-1 table 7 · SANS 10400-K

The wall

Deducted from the board count AND the field ties.
m
Both jambs of every opening: 2 × height, added up. Extra ties go here — see below.
m

The build-up

This changes the tie count more than anything else on this page.
Each extra board adds 35 mm: its knob plugs into the socket behind the one above.
%
Commercial, not code. Edit it or set it to 0.

What to order

LiteCel CD boards
Wall ties
Net wall area
Tie bundles of 100

The ties, in detail

ItemValueWhere it comes from
Cavity widthBoard build-up
Tie length requiredL ≥ cavity + 100 (50 mm embedment each leaf)
Tie typeSANS 10164-1 5.2.1.4(b), (c)
Code minimumSANS 10164-1 table 7
LiteCel setting-out425 × 600 = one board height
UsedThe greater of the two
Field tiesnet area × ties/m²
Extra at jambs≤300 mm of height, 5.2.1.4(a)
Extra at joints≤300 mm of height, 5.2.1.4(a)

Thermal

Board + cavity, R
m²K/W
EPS thickness
mm
These R-values are estimates. They are derived the same way the LiteCel brochure derives its own — from the declared grade, at λ ≈ 0,036 W/m·K — and no guarded-hot-box test exists for this board. Confirm with Technopol before relying on them in a SANS 10400-XA submission.
This is a take-off, not a design. Tie type, spacing, embedment, material and corrosion protection for any particular wall remain the designer's responsibility — SANS 28 appendix B puts the duty to specify on the purchaser. Coastal: within 30 km of the coast SANS 10400-K 4.2.1.4 calls for galvanising, not stainless; stainless is required only in tidal splash zones.