Structural cold-formed steel sections, rolled in-house from 1.9 mm — a heavier gauge than thin-gauge light steel frame (0.5–0.8 mm).
Page to be written
Technopol's Light Steel Frame is a turnkey cold-formed-steel building system: it roll-forms its own galvanised C/Z sections in-house in two tiers - heavy lipped-channel portal/lattice-truss frames and a light-gauge LSF stud system - and closes them in with its own EPS insulation and EIFS/DEFS render finishes.
| Property | Value | Standard |
|---|---|---|
| Steel gauge | from 1.9 (structural cold-formed sections) mm | — |
| Product / build-up | Cold-formed steel frame system in two tiers: heavy back-to-back lipped-channel (CFLC) portal & lattice-truss frames (125-300 mm deep) and light-gauge LSF studs (89 & 150 mm web), closed in with Technopol's own EPS insulated / EIFS-rendered envelope | SANS 517 ; SANS 10162-2 |
| Installed wall R-value (DEFS/LSF assembly) | 1.08 (0.8 mm stud) to 1.23 (0.6 mm stud) m²·K/W | — |
| Typical steel mass | 11.37 (12x10 m poultry house, 12° pitch, 4 bays) kg/m² | — |
| Frame section range (roll-former) | Web/waist 40-80, flange C 80-300 / Z 120-300, lip 10-25, plate 1.5-3.0; light-gauge studs 89 & 150 web; heavy portal sections to 300x75x20x2.0 mm | — |
| Documented portal clear spans | 15.4 and 17.4 (also 12x10 m house); ~12° duo-pitch m | — |
| Reaction-to-fire class (EPS core) | Class B-s1,d0 | SANS 53501-1 |
| Fire-resistance rating (NuClad LiteCore LSF wall) | REI 60 - R 60 / E 60 / I 60 (FR60, load-bearing) min | SANS 10177-2:2005 |
| Applicable standards & approvals | SANS 517:2009 (LSF building); SANS 10162-2 (cold-formed steel design); fire: SANS 53501-1 & SANS 10177-2; Agrément 2020/609 (LiteCore Building System) | — |
R-value is for the full DEFS/LSF wall assembly (89x38 stud @600 c/c, 14 kg/m³ cavity batt k=0.040, 15 mm gypsum + 12 mm FC board), not a single-product λ. Corresponding U ≈ 0.81-0.93 W/m²·K (derived). Technopol publishes no product thermal conductivity. Reaction-to-fire Class B-s1,d0 was tested on plain EPS at ±18.37 kg/m³ x 60 mm (Ignis Testing, authorised 17-08-2023, DJ Streicher Pr Eng). It applies to the EPS core, not to the bare steel frame. REI 60 applies only to the tested NuClad LiteCore LSF load-bearing wall (±240 mm; FRCell core 15 kg/m³ x 50 mm, 0.5 mm Chromadek exterior skin, LSF studs @635 c/c) - CSIR Fire Testing Services report FT 24/003 Issue 2 (2024), tested 2024, valid 5 years. Do not generalise this rating to other frame or envelope configurations. Steel mass is project-specific; 11.37 kg/m² is the verified 12x10 m poultry-house design (light sections: columns/rafters 150x50x20x2.0 B2B, purlins/haunch 100x50x20x2.0). The brochure's ~11 kg/m² for a 15.4 m portal is not backed by a primary weight sheet. Section sizes are roll-former capability ranges plus ad-hoc project sections, not a published fixed-size/tolerance catalogue. Portal connections use M16 Gr 4.8 bolts with 2 mm welded gusset plates. The ZincalMag/SpectraMag migration is a brochure claim with no primary source; the machine spec lists Q195/Q235 galvanised strip only. This is structural <b>cold-formed steel</b>, rolled from 1.9 mm upward — not thin-gauge ‘light steel frame’ (LSF), which is typically 0.5–0.8 mm and is designed to a different basis. Do not substitute one for the other on the strength of the name.
Values from Technopol technical documentation. Confirm the exact figures for your specification with Technopol.
The same product does a different job in each of these assemblies — each page states the target, the clause and the limits.
Each figure is labelled with how we know it — a named in-validity test, a supplier value, an in-house calculation, or a test whose validity has expired.
| Property | Value | Standard | Source report | Status |
|---|---|---|---|---|
| Installed wall R-value (DEFS/LSF assembly) | 1.08–1.23 m²·K/W | derived assembly | — | Calculated |
| Typical steel mass (12×10 m poultry house) | 11.37 kg/m² | in-house design | — | Calculated |
| Documented portal clear spans | 15.4 and 17.4 m | in-house design | — | Calculated |
| Reaction-to-fire class (EPS core) | B-s1,d0 | SANS 53501-1 | IT 23-08-00009 | Verified |
| Fire-resistance (NuClad LiteCore LSF wall) | REI 60 (R60/E60/I60, load-bearing) min | SANS 10177-2 | FT 24-003 | Verified |
Labels are defined on our data promise; every source report is on the test-report register.
A material specified for the wrong job fails you, then us. We would rather lose the order.
Real photographs of our own manufacturing and installed work — not renders. Click any image to enlarge.
PHOTO
PHOTO
PHOTO
PHOTO
PHOTO
PHOTONo project on the public register is tagged to this application yet. Ask us for references — we will send the ones that match your building type.
Send us the drawings. We will size it, detail it and quote it.
We release technical documentation to named engineers and specifiers so we can support you properly on the project. One entry unlocks everything.
We will not share your details. POPIA compliant.