LiteCore BricksLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photographLiteCore Bricks — photograph
The detail

Everything else, folded away

Specifications9 rows

LiteCore Bricks are large factory-cast, non-load-bearing lightweight walling blocks of EPS-beaded foamed cement used as infill inside a light-steel (SANS 517) or reinforced-concrete frame; external blocks are a 150 mm composite (two 45 mm foamed-cement skins around a 60 mm CavityLite EPS core) and internal blocks are 100 mm solid foamed cement, both 1200 x 340 mm.

PropertyValueStandard
Product / build-upNon-load-bearing EPS-beaded foamed-cement infill block. External 150 mm = 45 mm foamed cement + 60 mm CavityLite EPS core + 45 mm foamed cementinternal 100 mm = solid foamed cement (no core). Tongue-and-groove, stretcher bondAgrement 2020/609
Block dimensions1200 (L) x 340 (H) x 150 (external) / 100 (internal) mmAgrement 2020/609
Thermal resistance (external wall, total R)2.30 m²K/WAgrement 2020/609 (SANS 10400-XA)
Density400 (block); 15 (CavityLite EPS core) kg/m³Agrement 2020/609
Mass per brick18 kg
Wall self-weight60–68 kg/m²Technopol declared
Fire-resistance rating (external walls)120 (non-combustible, type FRR) minSANS 10400-T
Acoustic performance (between rooms)45 (DnT,w); Rw 45–48 across panel build-ups dBSANS 10218-1
Framing / application limitsNon-load-bearing infill onlymust sit within a SANS 517 steel or SANS 10100 RC frame with cast in-situ ring beams; wall dimensional limit 3500 mmAgrement 2020/609; SANS 517; SANS 10100

Thermal: 2.30 m²K/W is the certified total R-value of the plastered external wall build-up (12 mm plaster + 45 mm foamed cement + 60 mm EPS core + 45 mm foamed cement + 12 mm plaster, 174 mm overall). The datasheet also quotes R > 2.2 for the 150 mm brick alone. The bare foamed-cement thermal conductivity (λ) is not published, so no U-value per thickness can be stated. Compressive strength: the product is explicitly non-load-bearing infill; the strain and test method behind the >1.0 / <5 MPa figures are not stated. Density: factory QC 28-day dry densities measured higher than the 400–450 kg/m³ certified nominal (~493–510 kg/m³ for 150 mm blocks, ~547–597 kg/m³ for 100 mm blocks; source: LiteCore Block Densities.xlsx) — mix/grade dependent. Fire: the 120-minute rating is the SANS 10400-T deemed-to-satisfy classification for the plastered external LiteCore wall. A separate independent SANS 10177-2 test (report FT 24-003) achieved FR60 — Stability/Integrity/Insulation each 60 min — but on the NuClad LiteCore LSF assembly (Chromadek + plastered LiteCore on a light-steel frame), which is a different build-up, not the bare block wall. Do not generalise either figure to other assemblies. Acoustic: the Rw 45–48 dB figures are from mathematical modelling (Acusolv), not laboratory measurement; the 45 dB DnT,w is the Agrement-accepted between-room value.

Values from Technopol technical documentation. Confirm the exact figures for your specification with Technopol.

Performance data6 figures
PropertyValueStandard
Thermal resistance (external wall, total R)2.30 m²K/WAgrément 2020/609 (SANS 10400-XA)
Block dimensions1200 × 340 × 150/100 mmAgrément 2020/609
Density (block, certified nominal)400–450 kg/m³Agrément 2020/609
Fire-resistance (external wall, deemed-to-satisfy)120 minSANS 10400-T
Fire-resistance (NuClad LiteCore LSF assembly)FR60 (S/I/I 60) minSANS 10177-2
Acoustic performance (between rooms)45 (DnT,w) dBSANS 10218-1

Every test report and certificate behind these figures is on the test-report register.

Where it is used1 applications

The same product does a different job in each of these assemblies - each page states the target, the clause and the limits.

Cavity Wall Insulation

Technical documentation

The LiteCore Bricks kit

The full detail lives here — brochure, design guide, engineering specification and an interactive calculator. Everything below is the summary.

PDF
Product flyerOne page — what it is, key specifications, at a glance.
Download
PDF
Product brochureFull product overview, specifications and applications.
Download
PDF
Technical design guideFull design guidance, worked examples, standards references.
Download
PDF
Engineering specificationClause-referenced specification text for your tender documents.
Download
APP
Interactive calculatorSize the system and check performance in your browser.
Open
PDF
Installation guideStep-by-step site installation sequence.
Download

Ready to specify?

Send us the drawings. We will size it, detail it and quote it.

Request a spec or quote

Technical resource

Who should we send this to?

We release technical documentation to named engineers and specifiers so we can support you properly on the project. One entry unlocks everything.

We will email you this document, and we may follow up about it. We will not add you to anything else unless you tick the box. We do not share or sell your details. How we handle your information.