Insulated personnel doors for panel-built rooms and controlled environments.
Page to be written







The Technopol Personal Panel Door is a made-to-measure single-leaf pedestrian door whose leaf is cut from the same laminated EPS sandwich panel as LiteSpan walls — two Chromadek coated-steel skins bonded to a fire-retarded EPS (FRCel) core — hung in a lipped steel jamb that either clips over an EPS panel wall or fits inside a brick reveal.
| Property | Value | Standard |
|---|---|---|
| Product type / build-up | Made-to-measure single-leaf pedestrian doorleaf cut from Technopol laminated EPS sandwich panel (two Chromadek steel skins bonded to a fire-retarded EPS core), hung in a lipped steel jamb | — |
| Steel skins | Chromadek / galvanised coated steel, 0.3–0.5 (0.5 default) mm | — |
| Core material | Fire-retarded expanded polystyrene (FRCel); StoneWool or PIR core on request | — |
| Panel cover / laminated width | 1145 mm | — |
| Core / leaf (panel) thickness | 44–50 mm | — |
| Jamb (frame) | Lipped steel C-section gripping the leaf edge; 44, 50, 60, 75, 100 (75 typical); supplied in 6 m lengths mm | — |
| Standards & certification | Fire testing: SANS 53501-1 and SANS 10177-9/-11 (EPS core). No door-specific product standardAgrément SA 2020/609 covers the LiteCore system only, not this door | Agrément SA 2020/609 |
Core density is grade-dependent: the brochure and 2021 door-leaf calc specify 15 kg/m³ (wall grade); the current 1 May 2026 door-leaf calculator uses 24 kg/m³ (24DV high-traffic grade). No datasheet fixes a single definitive production grade. Reaction-to-fire class B-s1,d0 applies to the EPS core material only, tested as a 60 mm sheet at ±18.37 kg/m³ (SANS 53501-1, Ignis report 2023-08-17 Technopol, authorised 17 Aug 2023). This is a material reaction-to-fire class, NOT a fire-resistance (REI) rating; no FR30/FR60 fire-resistance result exists for the door leaf or assembly. The door is made-to-measure, ordered to 7 dimensions (A–G, all mm); the sizes listed are typical priced configurations, not a fixed size range. Jambs fit either over a Technopol EPS panel wall or inside a brick/masonry reveal. Steel-skin, panel-cover, core-thickness and 24 kg/m³ core-density values were confirmed by opening the May 2026 Door Leaf Calculator; the fire class was confirmed against the SANS 53501-1 test report.
Values from Technopol technical documentation. Confirm the exact figures for your specification with Technopol.
| Property | Value | Standard |
|---|---|---|
| Steel skins | 0.3–0.5 mm | |
| Core / leaf thickness | 44–50 mm | |
| Panel cover / laminated width | 1145 mm | |
| Reaction-to-fire class (EPS core) | B-s1,d0 | SANS 53501-1 |
Every test report and certificate behind these figures is on the test-report register.
The same product does a different job in each of these assemblies - each page states the target, the clause and the limits.
Insulated Roof, Wall & Ceiling PanelsCold Store & Refrigerated BuildingsAgricultural & Poultry Housing
Send us the drawings. We will size it, detail it and quote it.
We release technical documentation to named engineers and specifiers so we can support you properly on the project. One entry unlocks everything.
We will email you this document, and we may follow up about it. We will not add you to anything else unless you tick the box. We do not share or sell your details. How we handle your information.