A double-leaf masonry wall has an air cavity between the leaves that is doing very little thermal work, while mortar droppings bridge it and wall ties conduct through it. Cavity insulation fills that void with a fire-retardant EPS element that keys into the mortar courses, lifting the wall's thermal resistance and cutting HVAC load without changing the wall footprint or the bricklaying sequence. Important scope note: under SANS 10400-XA a double-skin (cavity) masonry wall is already DEEMED-TO-SATISFY, so this is not a compliance rescue for masonry — it is a performance upgrade (comfort, running cost, rational-design/energy-model route) and a compliance route only for lightweight or otherwise non-qualifying walls.
Layers listed outside → inside. The section is drawn to show the ORDER of the layers and where the Technopol product sits in it; the band widths are not to scale.
The drained-cavity element, and the newer of the two cavity boards: a 35 mm moulded EPS board whose knobs hold a clear 25 mm cavity against the outer leaf, so water that penetrates the face brick runs down the channels to the DPC and out through the weep holes instead of being bridged across. 425 x 1240 mm — the 425 mm height is five brick courses, which is also the wall-tie spacing. Where PolyKey fills the cavity, LiteCel CD insulates it and drains it.
View product →
The cavity-fill element: interlocking fire-retardant FRCel EPS cavity insulation, T&G edges keying into the mortar courses of a double-leaf masonry wall, 340 x 1200 x 60/40 mm.
View product →
Plain cut-to-size FRCel EPS sheet as an alternative cavity fill where the interlocking PolyKey profile is not wanted, or where a non-standard cavity width must be filled.
View product →
Alternative wall system, not a cavity insert: the LiteCore Building System is the only Technopol product with an Agrement SA certificate (2020/609), and only as a NON-LOAD-BEARING wall. Consider where the design is not a traditional double-leaf masonry cavity wall.
View product →
Alternative route when the cavity is unavailable (solid or existing wall): a separate continuous external EPS layer on top-hat rails, weather-skinned with bare 0.5 mm roll-formed PPGL/PPGI LiteClad profiles. LiteClad is a steel weatherskin only — NOT a composite or insulated panel — and adds negligible R on its own.
View product →
Every test report and certificate behind these figures is held by Technopol and is available on request.
| Property | Value | Standard |
|---|---|---|
| Thermal conductivity (lambda, k @10 degC) | <= 0.035 W/m.K | EPS grade datasheet value for HD/20DV (20 kg/m3) |
| Thermal resistance R of the 60/40 mm element (tested with wall ties) | 2.0 m2K/W | Guarded hot-box test |
| Nominal density / grade | 20 (HD / 20DV) kg/m3 | EPS grade datasheet |
| Compressive stress at 10% deformation | >= 110 kPa | EPS grade datasheet (grade-dependent) |
| Element size (H x L x thickness, T&G profile) | 340 x 1200 x 60/40 mm | Product geometry |
| Reaction-to-fire classification (EPS FRCel 20DV, 60 mm) | B-s1,d0 | SANS 53501-1 (Euroclass) |
| Fire-resistance (REI) rating of the element | None — no fire-resistance rating exists for an EPS cavity element | SANS 10177-2 |
| Quality management system (company credential) | ISO 9001:2015 certified | ISO 9001:2015 |
Enter the climatic zone and wall build-up. For a double-skin masonry wall it will confirm you are already deemed-to-satisfy; use it to see what cavity insulation buys you above the minimum, or to size a lightweight wall to the R >= 0.35 m2K/W floor. Then run ../../technical/thermal-bridge/ for the wall-tie psi-value before quoting any assembly U-value, and ../../technical/spec-writer/ for the clause text. External walls with a SURFACE DENSITY LIGHTER THAN 270 kg/m2 (light steel frame, timber frame, drywall, sandwich panel) must reach a minimum TOTAL R-value of 2.2 m2K/W in energy zones 1, 2, 6 and 7, and 1.9 m2K/W in zones 3, 4, 5 and 5H (SANS 10400-XA:2021, ch.3). And any walling with metal sheet, metal studs, metal tracks or metal battens fixed to each other SHALL have a thermal break. The 0.35 m2K/W figure applies to MASONRY types not covered by the standard provisions - it is NOT the lightweight-wall bar.
A material specified for the wrong job fails you, then us.
Benoni · Industrial (food processing)
Residential
Modular building
Education / campus
Send us the drawings. We will size it, detail it and quote it.
We release technical documentation to named engineers and specifiers so we can support you properly on the project. One entry unlocks everything.
We will email you this document, and we may follow up about it. We will not add you to anything else unless you tick the box. We do not share or sell your details. How we handle your information.