19 Rockridge
Residential

19 Rockridge

Johannesburg
The roof panel is the ceiling you see from the sofa — sheet, insulation and finished ceiling in one lay, with no fastener head in the weather face.
LocationJohannesburg
RoofLiteSpan 990 Standing Seam — Chromadek steel skins on an FRCel EPS core, 990 mm cover, white underside
Roof fixing (product spec)Concealed 1.2 mm galvanised clip at every support, two screws per clip — no fastener through the weather face. From the LiteSpan Standing Seam spec; no clip appears in any photograph of this job. What the photographs show is the result: no fastener head in the weather face
Minimum pitch (Standing Seam)3° — the datasheet minimum for the profile, not a measurement of this roof
CladdingLiteClad ClipClad — 270 mm cover, 0.5 mm pre-painted steel, concealed wafer-screw fix, all per the datasheet. Run vertically on this house
LiteSpan range type-test (not this roof)Class A &mdash; no water penetration at 1200 Pa. Measured on the 125 mm <b>990 IBR</b> specimen (exposed valley fix) in the SANS 54509 Initial Type Test, OTH-T-2309-04 cl. 13.13. This roof is <b>990 Standing Seam</b>: the concealed-clip seam is a different joint and was not the tested one. The figure evidences the range, not this installation.

19 Rockridge is a private house on a ridge in Johannesburg, looking north over the treed suburbs. The architecture is thin, low-pitched roof planes carried on steel and timber over glass, brick and stone, with deep overhangs. There is no loft and no ceiling void: the roof plane is the ceiling plane, inside and out.

Technopol supplied the roof and part of the external skin. The roof is LiteSpan 990 Standing Seam — Chromadek steel skins factory-bonded to a fire-retardant FRCel EPS core, 990 mm cover, white underside. The product spec gives the fixing as a concealed 1.2 mm galvanised clip at every support, two screws per clip. No clip is visible in any photograph of this job; what the photographs show is the consequence — no fastener head in the weather face, and nothing in the field of the roof but the seams. The upper walls are clad in LiteClad ClipClad, the 270 mm concealed-fix profile in 0.5 mm pre-painted steel, run vertically.

The demanding part of this job is that the panel is seen from both sides. One photograph here is a crew working on the laid panel outside, harnessed, at the far edge of the roof; another is the same panel type overhead, as the finished ceiling of the double-volume living room. There is no ceiling board under it: the panel joints are the ceiling joints, and the factory skin is the finish. There is no separate insulation over it either — the insulation is the core — but that is the composite build-up in the spec table, not something these photographs show, because no frame in this album looks down on a laid panel. That is what a composite panel has to earn: a soffit good enough to live under.

It also had to be thin and shallow. In the photograph at the top of this page the roof reads as a floating plane, a deep eaves overhang with no fascia bulk. The datasheet takes the Standing Seam profile down to 3° pitch, and because the clip is concealed there is no fastener line to detail around at the eaves.

The cladding is fixed the same way. Per the datasheet the wafer screw goes through the lip and the next sheet laps over it; in the photograph where the run stops, the finished stretch carries no fastener head on its face and the horizontal rails it lands on are still open on the sheathing. It meets raw brick and stone piers directly, without a cover trim.

On this building
On site

The photographs

Ours, taken on the job. Not renders.

Standing-seam roof panels being laid, the city on the horizon. Two men in fall-arrest harnesses work at the far edge; the pans run up the slope with an upstand seam at every joint and no fastener head anywhere in the field. A power cable and a rope lie across the laid surface.PHOTO
Standing-seam roof panels being laid, the city on the horizon. Two men in fall-arrest harnesses work at the far edge; the pans run up the slope with an upstand seam at every joint and no fastener head anywhere in the field. A power cable and a rope lie across the laid surface.
The finished double-volume living room, furnished and lived in. The ceiling is the underside of the roof panel - the panel joints are the only lines in it - crossed by dark steel beams, with a lit clerestory slot running at the head of the wall.PHOTO
The finished double-volume living room, furnished and lived in. The ceiling is the underside of the roof panel - the panel joints are the only lines in it - crossed by dark steel beams, with a lit clerestory slot running at the head of the wall.
The cut end of the roof panel at the eaves. The white foam core shows between the two steel skins, with the standing-seam ribs turned up on the weather face and the flat white skin below; the panel lands on a timber plate above the stone pier. Two men are on the roof beyond.PHOTO
The cut end of the roof panel at the eaves. The white foam core shows between the two steel skins, with the standing-seam ribs turned up on the weather face and the flat white skin below; the panel lands on a timber plate above the stone pier. Two men are on the roof beyond.

Building something like this?

Send us the section and we will tell you what fits.

Talk to someone technical More projects
Technical resource

Who should we send this to?

We release technical documentation to named engineers and specifiers so we can support you properly on the project. One entry unlocks everything.

We will email you this document, and we may follow up about it. We will not add you to anything else unless you tick the box. We do not share or sell your details. How we handle your information.