Sea-front house, Gansbaai
Residential

Sea-front house, Gansbaai

Gansbaai, Western Cape — the album is filed under that name. No frame in it carries a street sign, board or place name, and the EXIF is stripped, so the location is the register's word and not the photographs'.
The wall panel is fixed on the outside of the steel frame, so the insulation runs past the studs unbroken — and the same panel is then the sheathing and the base the cladding's own fixings screw into.
ApplicationLight steel frame house — LiteSpan panel fixed to the outside face of the frame as continuous insulation, sheathing and cladding substrate
Wall build-up seen in the framesCold-formed steel studs and K-bracing, then LiteSpan panel screw-fixed in horizontal courses on the OUTER face, unbroken across the studs
Panel coreExpanded polystyrene bead behind a thin steel facing — seen directly at a cut window reveal (photograph 1390) and again at a cut panel end (1093). Only the outer facing is visible at any cut edge in the album. Thickness, core grade, facing gauge and coating are not determinable from any frame
Cladding fixingAt the corner in photograph 1390, two dark grey folded brackets are screwed through the panel face, three screw heads each. Whether they are seam clips or corner cleats is not readable, and no fixing centres can be measured off a photograph
How the seam meets the panelThe standing-seam sheet is laid straight onto the panel face with no rail or batten between (1379, 1392), and the seams are closed on site with a hand seamer (1308)
Second finish on the same panelA notched-trowel bed of grey cementitious material worked directly onto the panel face (photograph 1497). The finished house has flat white elevations wherever there is no standing seam, but no frame links that finish to this bed
Roof build-upIsofoil reflective foil over light steel rafters, then the standing-seam sheet on the foil (1288, 1300, 1308). No panel in the roof. What sits between foil and sheet is not fully readable — light steel sections are lying on the foil in 1288
Mill stencil on the sheeting"COLORBOND (R) ULTRA steel made by BlueScope G300 CLN AZ200 U30 0.54 TCT (0.48 BMT)" — read at full resolution off two flashings, in photographs 1445 and 1446
What the stencil proves and does notIt proves single-skin 0,48 mm BMT / 0,54 mm TCT, G300, AZ200. It names the steelmaker who made the coil, not the roll-former. Technopol records the profile as LiteClad Standing Seam; the photographs do not
Foil label read on siteISOFOIL Reflective Foil Insulation, Industrial Double Reinforced Foil, 1250 mm × 40 m = 50 m², 9,20 kg, fire classification SANS 428 B/B1/2 (photograph 1260). That classification belongs to the foil, not to the panel or the cladding
CeilingsFlat white boards on a light steel lattice ceiling grid, with reflective foil over the rafters above and brown fibrous batt at the eaves. The batt is not an EPS product. No product marking is visible on the boards in any frame
SubstructureBrick substructure and podium, hollow-core slabs and a hot-rolled galvanised portal frame below the light steel storey — plank ends with round voids in photograph 838, galvanised hot-rolled sections and bolted end plates in 970
What is Technopol's on this jobThe wall panel and the cladding. The light steel frame, the lattice trusses, the hollow-core slabs and the ceiling batt are not attributed here, and no frame says who supplied them
What Technopol holds on this job2,028 frames in build order, pulled from a Google Photos album. EXIF stripped — no dates, no GPS, no camera. 333 of them are video poster frames, not photographs

A two-storey house on a coastal dune, and Technopol's record of it is an owner's build diary: 2,028 frames in build order, from excavation to the finished rooms. It is not a photographed job. The EXIF has been stripped by Google Photos, so there are no dates, no camera and no GPS on any frame, and about a sixth of the album is video poster frames rather than stills. Mixed in with the site pictures are kitchen renders, shop shelves and phone screenshots. This study is written from the stills, and it says where a claim comes from the photographs and where it does not.

The structure arrives in layers. Brick substructure, then a brick podium carrying hollow-core slabs and a hot-rolled galvanised portal frame, and on top of that a light steel frame. Photograph 1044 is that stage: lattice trusses arching over the slab in low sun, wall frames of cold-formed studs standing on the deck, men on scaffold. Everything the wall will have to deal with thermally is visible in that one frame — a stud every few hundred millimetres, top and bottom tracks, diagonal bracing, all of it steel and all of it running from inside to outside. The layers under it are there as context only: the hollow-core plank ends with their round voids show in photograph 838, and the galvanised hot-rolled sections with their bolted end plates in 970. Nothing in the album says who supplied any of that. Technopol's part of this job is the wall panel and the cladding.

Then the panel goes on, and it goes on outside. Photograph 1093 is the clearest frame in the album because it shows both conditions in one view: on the right the light steel frame stands bare, studs and bracing open to the sea; running away to the left the same frame is covered by LiteSpan panel in horizontal courses screw-fixed to its outer face. The panel passes across the studs. It is not cut between them and it is not returned into the frame. Photograph 1273 makes the same point at an external corner — the courses wrap the corner unbroken, and through the openings either side of it you look straight through at the frame behind: studs, K-bracing, lattice trusses, reflective foil, none of it touching the outer face. That is continuous insulation, and it is an observation from the picture rather than a calculation.

The second job the panel does is structural to the cladding, not to the building. Photograph 1390 is a window head at the corner where a bare panel elevation meets the standing seam. Two dark grey folded brackets are screwed to the panel face — three screw heads each, driven through the panel — and the cladding returns around the corner against them. Whether those brackets are seam clips or corner cleats cannot be read off the frame. What the frame does settle is that the cladding's fixings land in the panel, with no rail or batten between; and 1379, where the seam is being laid across a bare panel elevation, shows the same thing at full length. The same frame answers what the panel is made of: at the window reveal the cut edge is exposed, and it reads unmistakably as expanded polystyrene bead behind a thin steel facing. The wall panel is the insulation, the sheathing and the fixing base, and no separate substrate appears anywhere in the sequence.

It takes a wet finish too. Photograph 1497 is a plasterer on a scaffold board working a notched-trowel bed of grey cementitious material straight onto the panel below a window opening. The comb ridges are sharp, the untouched white panel face shows at the edges of the patch, and there are white flecks in the mix. On the elevations that are not clad in the standing seam — the gable end in the finished views — the wall is finished flat and white rather than seamed. Whether that white finish is the same material as the bed in 1497 is not something a photograph settles. What the sequence does show is that the same element takes the cladding's fixings on one face of the house and a wet finish on another.

The roof is not the same build-up, and it is worth being exact about that. Photograph 1288 shows Isofoil laid over the light steel rafters, with light steel sections lying on the foil waiting to go over it; in 1308 the standing seam is down on the foil, one man closing the seam with a hand seamer while a second screws the sheet home. A roll label in the album reads ISOFOIL Reflective Foil Insulation, Industrial Double Reinforced Foil, 1250 mm × 40 m = 50 m², 9,20 kg, fire classification SANS 428 B/B1/2 — that is read off the wrapper, not off a datasheet, and it is the foil's classification, not the panel's or the cladding's. The sheeting itself carries a mill stencil, legible in photographs 1445 and 1446: COLORBOND (R) ULTRA steel made by BlueScope, G300 CLN AZ200 U30, 0,54 TCT (0,48 BMT). A mill stencil names the steelmaker who made the coil, never the roll-former who profiled it. Technopol's record of the job is LiteClad Standing Seam and the owner confirms it; what the stencil independently proves is a single-skin 0,48 mm base metal thickness in AZ200 — thin painted sheet, not a panel. Roof and wall are different products here, and the photographs show it.

Inside, the ceilings hang from a light steel lattice grid. Photograph 1736 catches it open: the grid below, reflective foil stretched over the rafters above it, brown fibrous batt showing at the eaves. That batt is not an EPS product and nothing in the album ties it to Technopol. Photograph 1720 is the same idea closed — a raked ceiling in wide flat boards with fine butt joints, the sea through the window. Technopol records those boards as NuClad, the single-skin member of the LiteSpan family; nothing visible in any frame names them, so that attribution is the register's and not the album's. The rest is beyond what a photograph can settle: panel thickness, core grade, steel gauge and coating, fixing centres, U-values, thermal-bridging and air-tightness figures, any fire, acoustic or wind-load rating for the panel or the cladding, the frame's supplier, the client, the architect, the contractor, the floor area, the dates and the programme. Those are questions for Technopol.

On this building
On site

The photographs

Ours, taken on the job. Not renders.

Hand-seaming the roof. One roofer walks a yellow seaming tool along a standing seam while a second fixes the next sheet down; the silver reflective foil laid over the rafters shows in the strip still open beyond them.PHOTO
Hand-seaming the roof. One roofer walks a yellow seaming tool along a standing seam while a second fixes the next sheet down; the silver reflective foil laid over the rafters shows in the strip still open beyond them.
The panel turns the external corner in one plane. Through the two window openings the frame behind is completely visible - studs, K-bracing, lattice trusses and reflective foil - and none of it interrupts the outer face.PHOTO
The panel turns the external corner in one plane. Through the two window openings the frame behind is completely visible - studs, K-bracing, lattice trusses and reflective foil - and none of it interrupts the outer face.

Building something like this?

Send us the section and we will tell you what fits.

Talk to someone technical More projects
Technical resource

Who should we send this to?

We release technical documentation to named engineers and specifiers so we can support you properly on the project. One entry unlocks everything.