EPS structural fill for embankments, bridge abutments and services trenches — 1% the weight of soil.
Kit complete
Technopol Geofoam is engineered ultra-lightweight EPS fill (geofoam), supplied as large closed-cell moulded blocks that are field-cut and placed dry without compaction; grade-dependent properties span the EPS12–EPS30 ladder to ASTM D6817 / D7180.
| Property | Value | Standard |
|---|---|---|
| Product / build-up | Engineered ultra-lightweight EPS block fill (geofoam) — large closed-cell moulded blocks, field-cut, placed dry without compaction (~1% the weight of soil) | — |
| Density (grade span) | 12–30 kg/m³ | — |
| Thermal conductivity (λ) @10 °C | 0.033–0.045 W/m·K | — |
| Design load limit — compressive resistance @1% strain | 15–100 kPa | — |
| Compressive strength @10% strain | 60–200 kPa | — |
| Water absorption | < 4 % | — |
| Reaction-to-fire class (FR grade) | Class B-s1,d0 | SANS 53501-1 |
| Fire-resistance rating (REI) | None — reaction-to-fire classification only; EPS is combustible | — |
| Typical block size | 2500 × 1250 × 950 (typical; other sizes cut to order) mm | — |
| Applicable standards | ASTM D6817 (physical properties), ASTM D7180 (geotechnical design), ASTM D7557 (sampling) | ASTM D6817 / D7180 / D7557 |
Grade-dependent: density, λ and compressive values span the manufactured grade ladder (Technopol supplies EPS12/SD through EHD/EPS30). Per-grade @1% safe-working loads are 15/17/45/70/100 kPa for EPS12/15/20/24/30. Design sustained stress must stay ≤ the compressive resistance @1% strain (elastic limit); do not design to the @5%/@10% values (creep). The @10% figures are the failure-region strength, not a design load. Fire scope: Class B-s1,d0 applies to FR (flame-retardant) EPS and was established on a 60 mm sheet at ~18.4 kg/m³ (Ignis Test Lab, Cape Town; SANS 53501-1 report 17.08.2023, authorised DJ Streicher Pr Eng). It is not formally extended to every geofoam grade/thickness; standard (non-FR) geofoam is combustible and must be covered by slab, pavement or soil in the permanent works. λ range is the Technopol per-grade datasheet (0.033–0.045 W/m·K, @10 °C); the brochure summary quotes 0.030–0.038 W/m·K. Insulation is incidental — no R/U value per thickness is published for geofoam.
Values from Technopol technical documentation. Confirm the exact figures for your specification with Technopol.
The same product does a different job in each of these assemblies — each page states the target, the clause and the limits.
Cold Store & Refrigerated BuildingsUnder-Slab & Slab-Edge InsulationInverted (Protected-Membrane) RoofGeofoam Lightweight Civil Fill
Each figure is labelled with how we know it — a named in-validity test, a supplier value, an in-house calculation, or a test whose validity has expired.
| Property | Value | Standard | Source report | Status |
|---|---|---|---|---|
| Density (grade span) | 12–30 kg/m³ | ASTM D6817 | — | Provisional |
| Thermal conductivity λ @10°C | 0.033–0.045 W/m·K | — | Provisional | |
| Compressive resistance @1% strain (design limit) | 15–100 kPa | ASTM D7180 | — | Provisional |
| Compressive strength @10% strain | 60–200 kPa | ASTM D6817 | — | Provisional |
| Reaction-to-fire class (FR grade) | B-s1,d0 | SANS 53501-1 | IT 23-08-00009 | Verified |
Labels are defined on our data promise; every source report is on the test-report register.
A material specified for the wrong job fails you, then us. We would rather lose the order.
Menlyn, Pretoria · Casino / hotel
Institutional / banking
Commercial
Send us the drawings. We will size it, detail it and quote it.
We release technical documentation to named engineers and specifiers so we can support you properly on the project. One entry unlocks everything.
We will not share your details. POPIA compliant.